Due to a problem when using Intel® Quartus® Prime Pro Edition Software versions 21.1, 21.2, and 21.3 and Intel® Stratix® 10 SmartVID devices with a VID fuse value of 900mV, there is a missing VOUT_COMMAND in PMBus Master Mode. This causes the external voltage regulator to not be configured to the expected voltage level resulting in configuration failure.
To work around this problem, use the patch for Intel® Quartus® Prime Pro Edition Software version 21.3 below.
For earlier versions of Intel® Quartus® Prime Pro Edition Software, contact Intel.
This problem is fixed starting from Intel® Quartus® Prime Pro Edition Software version 21.4