Article ID: 000087345 Content Type: Error Messages Last Reviewed: 12/21/2022

Warning: <clk>/asmi_parallel2.clk: asmi_parallel2.clk requires 50000000Hz, but source has frequency of 100000000Hz

Environment

  • Intel® Quartus® Prime Pro Edition
  • ASMI Parallel II Intel® FPGA IP
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    This warning message will appear when the input clock for the ASMI Parallel II IP is not set to 'exactly' 50MHz. The maximum input clock frequency for the ASMI Parallel II IP is 50MHz.

    Thus, the warning message will be cleared when the input clock is set to 50MHz. If you set the input clock below 50MHz, you can ignore the warning message.

    Resolution

    This problem is fixed in Intel® Quartus® Prime Software version 17.1.

    Related Products

    This article applies to 1 products

    Intel® Arria® 10 FPGAs and SoC FPGAs