This warning message may be generated for designs using the Serial Digital Interface (SDI) MegaCore® Function software version 13.0 or 13.1.
Critical Warning (18061): Ignored Power-Up Level option on the following registers
Critical Warning (18010): Register <Instance name>|sdi_txrx_port:sdi_txrx_port_gen[0].u_txrx_port|sdi_tr_gxb_interface:gen_u_gxb_if.u_gxb_if|sdi_tr_gxb_ctrl_s2gx:alt2gxb_ctrl.u_gxb2_ctrl|t_rst_analog will power up to High
Critical Warning (18010): Register <Instance name>|sdi_txrx_port:sdi_txrx_port_gen[0].u_txrx_port|sdi_tr_gxb_interface:gen_u_gxb_if.u_gxb_if|sdi_tr_gxb_ctrl_s2gx:alt2gxb_ctrl.u_gxb2_ctrl|t_rst_sdi will power up to High
Critical Warning (18010): Register <Instance name>|sdi_txrx_port:sdi_txrx_port_gen[0].u_txrx_port|sdi_tr_gxb_interface:gen_u_gxb_if.u_gxb_if|sdi_tr_gxb_ctrl_s2gx:alt2gxb_ctrl.u_gxb2_ctrl|t_locktorefclk will power up to High
Critical Warning (18010): Register <Instance name>|sdi_txrx_port:sdi_txrx_port_gen[0].u_txrx_port|sdi_tr_gxb_interface:gen_u_gxb_if.u_gxb_if|sdi_tr_gxb_ctrl_s2gx:alt2gxb_ctrl.u_gxb2_ctrl|search_hd_only will power up to High
Critical Warning (18010): Register <Instance name>|sdi_txrx_port:sdi_txrx_port_gen[0].u_txrx_port|sdi_tr_gxb_interface:gen_u_gxb_if.u_gxb_if|sdi_tr_gxb_ctrl_s2gx:alt2gxb_ctrl.u_gxb2_ctrl|search_sd_only will power up to High
Critical Warning (18010): Register <Instance name>|sdi_txrx_port:sdi_txrx_port_gen[0].u_txrx_port|sdi_tr_gxb_interface:gen_u_gxb_if.u_gxb_if|sdi_tr_gxb_ctrl_s2gx:alt2gxb_ctrl.u_gxb2_ctrl|search_3g_only will power up to High
Critical Warning (18010): Register <Instance name>|sdi_txrx_port:sdi_txrx_port_gen[0].u_txrx_port|sdi_tr_gxb_interface:gen_u_gxb_if.u_gxb_if|sdi_tr_gxb_ctrl_s2gx:alt2gxb_ctrl.u_gxb2_ctrl|t_rc_dig_rst will power up to High
Critical Warning (18010): Register <Instance name>|sdi_txrx_port:sdi_txrx_port_gen[0].u_txrx_port|sdi_tr_gxb_interface:gen_u_gxb_if.u_gxb_if|sdi_tr_gxb_ctrl_s2gx:alt2gxb_ctrl.u_gxb2_ctrl|t_hd_sdn will power up to High
Critical Warning (18010): Register <Instance name>|sdi_txrx_port:sdi_txrx_port_gen[0].u_txrx_port|sdi_tr_gxb_interface:gen_u_gxb_if.u_gxb_if|sdi_tr_gxb_ctrl_s2gx:alt2gxb_ctrl.u_gxb2_ctrl|t_reset_rate_detect will power up to High
You can safely ignore this critical warning message.
This will be fixed in a future release of the Quartus® II software.