Article ID: 000086693 Content Type: Troubleshooting Last Reviewed: 10/04/2018

Why is Cyclone® III Remote Update MSM Register not updated after reconfiguration?

Environment

  • Remote Update Intel® FPGA IP
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    After performing remote system upgrade, you will observed that the Master State Machine (MSM) register of the Remote Update IP is not updated. The reason is that you are reading the MSM register too early after reconfiguration.

    Resolution

    You will need to wait at least 600us delay after re-configuration before reading the MSM register of remote update IP.

    Related Products

    This article applies to 1 products

    Cyclone® III FPGAs