Article ID: 000086662 Content Type: Error Messages Last Reviewed: 03/13/2023

Error(19192): File .sof is incompatible - please recompile design using ACDS 20.4 Build 44 or later. This is because the SOF does not have tracking feature

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem with the Reset Release Intel® FPGA IP, a SOF generated in Intel® Quartus® Prime Pro Edition Software version 20.3 and earlier for all Intel Agilex® devices will be prohibited to be used in Intel® Quartus® Prime Software Programmer and Programming File Generator in version 21.1 and above regardless of whether the Reset Release Intel® FPGA IP is instanced or not.

    Resolution

    To fix this issue, recompile the design in Intel® Quartus® Prime Pro Edition Software starting from version 21.1 and above.