Article ID: 000086661 Content Type: Troubleshooting Last Reviewed: 03/07/2022

Why is the Intel® Stratix® 10 HPS held in reset after a reconfiguration with a partially signed image?

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 21.1 and patch 0.06, you may observe that the HPS will not come out of reset in a design where authentication is needed when configuring a signed bitstream after configuring a partially signed or unsigned bitstream. 

    Resolution

    To work around this issue perform a power-on reset (POR). 

    This problem is fixed starting with the Intel® Quartus® Prime Pro Edition Software version 21.2.

    Related Products

    This article applies to 1 products

    Intel® Stratix® 10 SX SoC FPGA