Critical Issue
The Clocked Video Input II IP core erroneously reports the interlaced fields F0 as F1 and F1 as F0 when you turn on the Extract field signal parameter.
When you turn on the Extract field signal parameter, the Clocked Video Input II IP core adds a logic to extract field signal from the V-sync and H-sync timings. This extraction is not necessary for the following conditions:
- Video interface standards like serial digital interface (SDI) where interlaced informaton is embedded in the header data.
- External
vid_f
signal is available to the Clocked Video Input II IP core indicating the field status of the incoming video data.
There is no workaround for this issue.
This issue will be fixed in a future version of the Clocked Video Input II IP core.