Description
Due to a problem in the Quartus® II software version 15.0.2 and earlier, phase_done may not assert after a phase shift by phase_en pulse in the gate-level simulation of dynamic phase shift with Altera PLL IP.
This problem affects simulation only.
Resolution
This problem is fixed in the Intel® Quartus® Prime Standard Software version 16.0