Article ID: 000082994 Content Type: Error Messages Last Reviewed: 04/05/2023

Internal Error: Sub-system: FIOMGR, File: /quartus/fitter/fiomgr/fiomgr_reserve_pin_op_impl.cpp, Line: 5002

Environment

  • Quartus® II Subscription Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    This internal error may be generated by the Quartus® II software when targeting MAX® 10 devices and setting the default IO standard to 3.0V or 3.3V.

    Resolution

    In the Quartus® II software, choose a default IO standard of 2.5V or below from the Device and Pin Options. Then, use the Assignment Editor or the Pin Planner to assign the desired 3.3V or 3.0V IO standard to the respective pins.

    This problem was fixed in Intel® Quartus® software version 15.0

    Related Products

    This article applies to 1 products

    Intel® MAX® 10 FPGAs