Article ID: 000081767 Content Type: Troubleshooting Last Reviewed: 10/12/2011

For some Stratix V block types, look in the Setup Summary report and the Hold Summary report for clear and asynchronous recovery and removal timing data

Environment

  • Quartus® II Subscription Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT

    Critical Issue

    Description

    For some Stratix V block types, the TimeQuest Timing Analyzer might report recovery and removal timing for clear and asynchronous reset signals in the Setup Summary report and the Hold Summary report, instead of in the Recovery Summary report and the Removal Summary report. The affected block types are:

    • M20KLABREAD_FIFOHSSI_8G_TX_PCSHSSI_8G_RX_PCSHSSI_10G_TX_PCS
    Resolution

    To view recovery and removal timing data for these blocks, look in the setup and hold reports.

    Related Products

    This article applies to 1 products

    Show all