Critical Issue
Inconsistency between module definition and instantiation may cause some simulators to produce an error message.
The workaround for this issue is to manually edit the oct_control.v
and clock_pair_generator_config.v
files,
and remove specific port names from each, as described below.
File:
<variation_name>/rtl/<variation_name>_clock_pair_generator_config.v
Module:
arriaii_pseudo_diff_out
Instance:
pseudo_diffa_0
Port names to remove:
.dtc� .dtcbar� .oebout� .oeout� .dtcin� .oein
File:
<variation_name>/rtl/<variation_name>_oct_control.v
Module:
arriaii_termination_logic
Instance:
sd2a_0
Port names to remove:
.scanout� .s2pload� .scanclk� .scanenable� .scanin� .serdata