Article ID: 000080107 Content Type: Troubleshooting Last Reviewed: 09/26/2011

The Quartus II Fitter Reports Error When Separate TX and Duplex TX Are Assigned in the Same Transceiver Quad

Environment

  • Quartus® II Subscription Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT

    Critical Issue

    Description

    For designs with the Enable PLL Reconfiguration option turned on and targeting Cyclone IV GX devices, the Quartus II Fitter reports an error when separate TX and duplex TX SDI instances are assigned in the same transceiver quad.

    This issue affects all designs targeting Cyclone IV GX devices with the Enable PLL Reconfiguration option turned on.

    The design cannot be fitted in the device.

    Resolution

    Uses separate RX and TX SDI instances to fit more than 1 SDI transmitter in a transceiver quad.

    This issue will be fixed in a future version of the SDI MegaCore function.

    Related Products

    This article applies to 1 products

    Intel® Programmable Devices