Article ID: 000079325 Content Type: Troubleshooting Last Reviewed: 12/15/2014

Command-line DSE II compilation results are not visible in the DSE II GUI

Environment

  • Quartus® II Subscription Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT

    Critical Issue

    Description

    You initiated a compilation or design exploration with the Design Space Explorer (DSE) II command-line tool but cannot view the results in the DSE II GUI. The DSE II GUI cannot show the results because a compilation name (--group-id) was not specified for the command-line compilation.

    Resolution

    Edit the <revision>.dse file located in the project directory to add or change the group_id argument (group_id = <compilation name>. The default name is dse1_<revision_name> if a compilation name is not explicitly specified.

    Related Products

    This article applies to 1 products

    Intel® Programmable Devices