Yes. MAX 7000AE, MAX 7000B, and MAX 3000A devices support a feature that allows you to interrupt in-system programming without damaging the device. All I/O pins will remain tri-stated until programming is successfully completed.
This feature is implemented using an internal EEPROM bit called the ISP_Done