Article ID: 000077271 Content Type: Error Messages Last Reviewed: 02/25/2013

Error (169058): I/O standard HiSpi on input I/O pin cannot have Termination logic option setting Differential

Environment

  • Quartus® II Subscription Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Quartus® II software versions 12.1 and earlier, you may receive this error message when using the HiSpi I/O standard with differential on-chip termination (OCT). This problem affects designs targeting Cyclone® V devices.

    Resolution

    To work around this problem use the LVDS I/O standard.

    This problem is fixed beginning with the Quartus II software version 12.1 SP1.

    Related Products

    This article applies to 6 products

    Cyclone® V SX SoC FPGA
    Cyclone® V GT FPGA
    Cyclone® V GX FPGA
    Cyclone® V ST SoC FPGA
    Cyclone® V E FPGA
    Cyclone® V SE SoC FPGA