Article ID: 000076644 Content Type: Troubleshooting Last Reviewed: 03/08/2023

Can the slew rate be changed in the EMIF IP for Intel Agilex® 7 FPGA devices?

Environment

  • Intel® Quartus® Prime Pro Edition
  • Memory Interfaces and Controllers
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 20.2 and earlier, the slew rate parameter in the EMIF IP for Intel Agilex® 7 FPGA devices cannot be changed.

     

     

    Resolution

    This problem is fixed starting with the Intel® Quartus® Prime Pro Edition Software version 20.3.

     

    Related Products

    This article applies to 1 products

    Intel Agilex® 7 FPGAs and SoC FPGAs