Article ID: 000075473 Content Type: Troubleshooting Last Reviewed: 09/11/2012

*** Fatal error: Module: quartus_fit.exe Exception: Access Violation^^Stack Trace:^^00bc60a7: CDB_ATOM_OTERM::begin_usage() 0x1b (db_cdb_atom)^^00bc6154: CDB_ATOM_OTERM::get_any_usage_as() 0x26 (db_cdb_atom)^^040747c9:

Environment

BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

*** Fatal error: Module: quartus_fit.exe Exception: Access Violation<br>Stack Trace:<br>00bc60a7: CDB_ATOM_OTERM::begin_usage() 0x1b (db_cdb_atom)<br>00bc6154: CDB_ATOM_OTERM::get_any_usage_as() 0x26 (db_cdb_atom)<br>040747c9: BPM_BOUNDARY_PORT_CHECKER::verify_atom_info() 0x2f6c.

 

This error may occur in the Quartus® II software version 5.0 when the physical synthesis register retiming option is enabled, and incremental compilation is turned on.

 

The problem has been fixed in the Quartus II software version 5.0 SP1.

To avoid this error in the Quartus II software version 5.0, turn off register retiming in the Physical Synthesis page under Fitter Settings in the Settings dialog box (Assignments menu).

Related Products

This article applies to 1 products

Stratix® FPGAs