Article ID: 000074579 Content Type: Troubleshooting Last Reviewed: 12/22/2017

Why does MAX 10 On-Chip Flash IP core read incorrect data at odd address?

Environment

  • Intel® Quartus® Prime Standard Edition
  • Intel® Quartus® Prime Lite Edition
  • On-Chip Flash Intel® FPGA IP
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem of Intel® Quartus® Prime Standard Edition and Lite Edition software version 17.0 Update 2 or earlier, you may see incorrect data at odd address, when using the On-Chip Flash IP core in MAX® 10.

    When reading data at odd address, you may see the data of the previous address.

    Resolution

    This problem has been fixed in Intel® Quartus® Prime Standard Edition and Lite Edition software version 17.1.

    Update your On-Chip Flash IP core using the software version 17.1 onward and recompile your design project.  

    Related Products

    This article applies to 1 products

    Intel® MAX® 10 FPGAs