    Description

    The Power Analyzer report in the Quartus® II software up to version 12.1 SP1 does not show a voltage supply for VCCA_FPLL in Cyclone® V devices.  This is a mistake with the voltage supply labels in the Current Drawn from Voltage Supplies Summary.  The current drawn from VCCA_FPLL is shown as VCCEH_GXB in this report. 

    VCCEH_GXB is not a valid Cyclone V device family power supply name.

    Resolution

    Use the current values reported for VCCEH_GXB for your power estimation of VCCA_FPLL.

    This problem is fixed in the Quartus® II software version 13.0