Article ID: 000073916 Content Type: Troubleshooting Last Reviewed: 08/06/2024

Why does Agilex™ 7 device Remote System Update fail to transition from one image to another?

Environment

  • Intel® Quartus® Prime Pro Edition
  • Remote Update Intel® FPGA IP
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    In the Quartus® Prime Pro Edition Software version 20.4, you might see Remote System Update (RSU) fails to transition from the bitstream (.rpd) generated in Quartus® Prime Pro Edition Software version 20.4 to an older image (e.g. bitstream (.rpd) generated in Quartus® Prime Pro Edition Software version 20.3 or earlier) when using Agilex™ 7 devices.

    For HPS devices, the RSU update cannot work correctly after an HPS cold reset, regardless of the bitstream version.

    Affected devices are Agilex™ 7 FPGA —AGFA014R24A and AGFB014R24A ES devices.

    Resolution

    To work around this problem, download and install the following patch 0.03 for Quartus® Prime Pro Edition Software version 20.4:

    This problem is fixed beginning with the Quartus® Prime Pro Edition Software version 20.4.

    Related Products

    This article applies to 1 products

    Intel Agilex® 7 FPGAs and SoC FPGAs F-Series