Article ID: 000073915 Content Type: Troubleshooting Last Reviewed: 03/07/2022

Why does the Intel® Stratix® 10 devices Temperature Sensor IP or Voltage Sensor IP hang in the Intel® Quartus® Prime Pro Edition Software versions 21.1 and 21.2? 

Environment

  • Intel® Quartus® Prime Pro Edition
  • Temperature Sensor Intel® Stratix® 10 FPGA IP
  • Voltage Sensor Intel® Stratix® 10 FPGA IP
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT

    Critical Issue

    Description

    Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 21.1 and 21.2, you may encounter that the Intel® Stratix® 10 devices are not functioning as expected when reading the temperature or voltage using the Temperature Sensor IP or Voltage Sensor IP. The rsp_valid and rsp_data might not be responding.

    Resolution

    To avoid this error, download and install the following patch for Intel® Quartus® Prime Pro Edition Software v21.2:

    This problem is fixed starting with the Intel® Quartus® Prime Pro Edition Software version 21.3.

     

    Related Products

    This article applies to 1 products

    Intel® Stratix® 10 FPGAs and SoC FPGAs