Article ID: 000073682 Content Type: Troubleshooting Last Reviewed: 08/03/2023

Does the EMIF Toolkit Efficiency Monitor and Protocol Checker support the Arria® V and Cyclone® Hard Memory Controller?

Environment

  • Quartus® II Software
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    No, the EMIF Toolkit Efficiency Monitor and Protocol Checker do not support any protocol's Arria® V and Cyclone® V Hard Memory Controllers (DDR3, DDR2, LPDDR2).

    Only the soft memory controllers can be used with the EMIF Toolkit Efficiency Monitor and Protocol Checker.  

    Resolution

    There is no fix planned.

    Related Products

    This article applies to 10 products

    Cyclone® V GT FPGA
    Arria® V GT FPGA
    Cyclone® V GX FPGA
    Arria® V GX FPGA
    Cyclone® V ST SoC FPGA
    Arria® V SX SoC FPGA
    Arria® V ST SoC FPGA
    Cyclone® V E FPGA
    Cyclone® V SE SoC FPGA
    Cyclone® V SX SoC FPGA