"Resume on AC Power Loss" When Set to "Power On" Fails

Content Type: Troubleshooting   |   Article ID: 000091298   |   Last Reviewed: 10/13/2022

Description

Resume on AC Power Loss when set to Power On fails using syscfg utility in M50CYP server system

Error Message : Failed to set "BIOS::Server Management::Resume on AC Power Loss", "Power On" is an invalid value, skip this item.

syscfg

Resolution

This is an expected behavior since Resume On AC Power Loss change is not supported through Syscfg.

  1.  Syscfg /prp command can be used to change Power Restore Policy - # syscfg /prp {off | on | restore} - power restore policy can be turned on/off or restored. 
  2. User can also use ipmi command to change it, command as below:

    Ipmitool raw 0 6 0/1/2/3 always power off/last effect state/always power up/no change