How to Set Up “Serial over LAN” for Intel® Server Boards and Systems Based on Intel® 62X Chipset

Content Type: Install & Setup   |   Article ID: 000059471   |   Last Reviewed: 10/14/2022

Description

Unable to access the server through SOL

Resolution

Method 1:

  1. Enter BIOS, click Advanced tab, select Serial Port Configuration, enable Serial A Enable option.
  2. Go to Server Management tab, select Console Redirection, enable SOL for BaseBoard Mgmt, SOL for BaseBoard Mgmt2 and SOL for Dedicated Mgmt NIC options, enable Serial Port A under Console Redirection option.
  3. Press F10 to save and exit.
  4. Login to BMC web console, click Configuration tab, select SOL, under Serial Over LAN, select Channel-1 from the LAN channel dropdown, click the checkbox Enable SOL for BaseBoard Mgmt and select Save. Repeat the same for Channel-2 and Channel-3.
  5. Restart server
  6. Login into BMC web console, select Remote control tab, select Launch SOL from the list, click Launch SOL button.

If above method does not work, follow Method 2.

Method 2:

  1. Enter BIOS, click Advanced tab, select Serial Port Configuration, enable Serial A Enable option.
  2. Go to Server Management tab, select Console Redirection, disable SOL for BaseBoard Mgmt & SOL for BaseBoard Mgmt2,  enable SOL for Dedicated Mgmt NIC, enable  Serial Port A and disable Serial Port B under Console Redirection option.
  3. Press F10 to save and exit.
  4. Login to BMC web console, click Configuration tab, select SOL, under Serial Over LAN, select Channel-3 from the LAN channel dropdown, click the checkbox Enable SOL for BaseBoard Mgmt and select Save.
  5. Restart server
  6. Login into BMC web console, select Remote control tab, select Launch SOL from the list, click Launch SOL button.

Additional information

Refer page 131 in Bios Setup User Guide for S2600 family for console redirection option.

Refer page 75, 82 in BMC Web Console User Guide for SOL configuration and Remote control launch SOL.

Use below IPMI command to check if the SOL has been correctly configurated.
Ipmitool -I lanplus -H <IP_ADDRESS> -U <USER> -P <PASSWORD> sol

Related Products

This article applies to 72 products.

Discontinued Products

Intel® Server Board D40AMP1SB Intel® Server Board S1200SP Family Intel® Server Board S1200SPL Intel® Server Board S1200SPLR Intel® Server Board S1200SPO Intel® Server Board S1200SPOR Intel® Server Board S1200SPS Intel® Server Board S1200SPSR Intel® Server Board S2600BPB Intel® Server Board S2600BPBR Intel® Server Board S2600BPQ Intel® Server Board S2600BPQR Intel® Server Board S2600BPS Intel® Server Board S2600BPSR Intel® Server Board S2600CW Family Intel® Server Board S2600CW2 Intel® Server Board S2600CW2R Intel® Server Board S2600CW2S Intel® Server Board S2600CW2SR Intel® Server Board S2600CWT Intel® Server Board S2600CWTR Intel® Server Board S2600CWTS Intel® Server Board S2600CWTSR Intel® Server Board S2600KP Intel® Server Board S2600KPF Intel® Server Board S2600KPFR Intel® Server Board S2600KPR Intel® Server Board S2600STB Intel® Server Board S2600STBR Intel® Server Board S2600STK Intel® Server Board S2600STQ Intel® Server Board S2600STQR Intel® Server Board S2600STS Intel® Server Board S2600TP Intel® Server Board S2600TPF Intel® Server Board S2600TPFR Intel® Server Board S2600TPR Intel® Server Board S2600WF0 Intel® Server Board S2600WF0R Intel® Server Board S2600WFQ Intel® Server Board S2600WFQR Intel® Server Board S2600WFT Intel® Server Board S2600WFTR Intel® Server Board S2600WT Family Intel® Server Board S2600WT2 Intel® Server Board S2600WT2R Intel® Server Board S2600WTT Intel® Server Board S2600WTTR Intel® Server Board S7200AP Family Intel® Server Board S7200AP Intel® Server Board S7200APR