Skip To Main Content
Support Knowledge Base

Unable to Run OpenVINO™ Simultaneously on Three or More Field Programmable Gate Array* (FPGA) Devices

Content Type: Product Information & Documentation   |   Article ID: 000059242   |   Last Reviewed: 05/20/2022

Environment

OpenVINO 2020.3

Description

Unable to do inference on the same model using three FPGA cards simultaneously.

Resolution

OpenVINO can support multiple FPGA devices simultaneously if they are running different models in each device. An example is given below:

  • FPGA Device 1: Object Detection with SSD-VGG Sample
  • FPGA Device 2: Image Segmentation Sample with FCN-8.
  • FPGA Device 3: Object Detection for Faster R-CNN Sample
  • FPGA Device 4: Image Classification Sample with Alexnet.

Supported OpenVINO FPGA Configurations:

  • Same model - maximum 2 FPGA devices
  • Different model - more than 2 FPGA devices with different models in each FPGA device

Additional information

Refer to Multiple FPGA Devices Support for more information.

Refer to Product Change Notice for FPGA support information.