Chassis Compatibility List for Intel® Server Board S2600ST Family

Documentation

Compatibility

000026937

01/12/2023

Tested Intel® Server Chassis list
Reference chassis list
 
Tested Intel® Server Chassis list

Intel® Server Chassis P4304XXMUXX
  • An integrated Intel® Server Chassis P4000, pedestal chassis, rackable1
  • Standard control panel
  • Fixed 4 x 3.5 HDD support, no backplane, 4 HDD power connectors, fan-out SATA cable
  • Hot Swap bezel (FUPBEZELHSD2)
  • Fixed EMI cover
  • Spare half EMI shield, to be used if one HS drive cage is installed, in the accessory box
  • Ready for hot swap drive support
    • Sold separately: HS drive cage
  • No CPU heatsinks
  • Five redundant/hot swap 80-mm system fans
  • Processor/memory air duct
  • Quick user guide
  • Power supply required: 750W or 1600W
1 Rails aren't included.

Intel® Server Chassis P4304XXMFEN2

(Product is End of Life)

  • An integrated Intel® Server Chassis P4000, pedestal chassis, rackable1
  • Standard control panel
  • Fixed 4 x 3.5 HDD support, no backplane, four HDD power connectors, one 4-port fan-out SATA cable
  • Ready for hot swap drive support
    • Sold separately: HS drive cage and front bezel with door
  • No CPU heatsinks
  • Two fixed 120-mm system fans
  • Fixed 550W PSU
  • Processor/memory air duct
  • Fixed bezel (FUPBEZELFIX2)
  • Fixed EMI cover
  • Spare hot swap EMI cover
  • Quick user guide
1 Rails aren't included.

Reference chassis list

The reference chassis list includes third-party chassis tested for the Intel® Server Board S2600ST Family. Chassis are tested to see if they provide adequate airflow to meet individual manufacturer temperature specifications.

Vendor Model Chassis type Power supply Unpackage shock test Thermal test level Driver support
AIC RSC-2AT Rack H/S Pass with 25G 3 A
AIC RSC-2ET Rack H/S Pass with 25G 3 A
AIC RSC-3ET Rack H/S Pass with 25G 3 A
AIC RSC-4BT Rack H/S Pass with 25G 2 A
AIC RSC-4ET Rack H/S Pass with 25G 2 A
Chenbro RM13304 Rack H/S Pass with 25G 2 A
Chenbro RM23812 Rack H/S Pass with 25G 1 A
Chenbro RM31616 Rack H/S Pass with 25G 1 A
Chenbro RM41824 Rack H/S Pass with 25G 1 A
In-Win RS10402M Rack Single Pass with 25G 4 A
In-Win RS31604 Rack H/S Pass with 25G 4 A
In-Win RS42404 Rack H/S Pass with 25G 4 A
Note

Results are posted when new chassis are tested.

Power supply

  • H/S = Hot Swap Redundant
  • Single = Single power supply

Thermal test level

Thermal testing is done on Intel® Server Boards for all listed third-party reference chassis. The Intel® Server Board is configured to use a generic fan control scheme that runs all attached system fans at 100-percent pulse width modulation (PWM). The generic fan control scheme is set by selecting the OTHER CHASSIS option using the FRUSDR Configuration Utility.

Results aren't guaranteed if the fan control PWM rate is reduced or changed from the tested configuration. If you change the PWM rate, you're responsible for all required thermal validation to make sure that the system configurations meet the maximum thermal limits.

The table lists the chassis configuration summary and the highest level of Intel thermal testing achieved.

Level Processor Maximum speed CPU TDP Manufacturing process technology Ambient temperature
1 Intel® Xeon® Platinum Scalable Processor 2.1 GHz 165W 14 nm 35° Celsius
2 Intel® Xeon® Platinum Scalable Processor 2.7 GHz 165W 14 nm 32.5° Celsius
3 Intel® Xeon® Gold Scalable Processor 2.6 GHz 150W 14 nm 32.5° Celsius
4 Intel® Xeon® Gold Scalable Processor 2.7 GHz 165W 14 nm 35° Celsius