TA-1125: Fail to Initialize the Operating System Video Driver for the ASPEED* Base Management Controller (BMC)
TA-1125: Fail to initialize the operating system video driver for the ASPEED* Base Management Controller (PDF)
Intel® has discovered an issue in which the host fails to initialize the operating system video driver for the ASPEED* Baseboard Management Controller (BMC). Headless or remote management environments are not affected.
Intel has confirmed that the failure has no bearing on system performance; it only impacts local video graphics. In detail, when the operating system loads, the OS-embedded ASPEED* video driver is not able to access a portion of the BMC memory space. Therefore, the process stalls.
Size: 378 KB
Date: August 2017
Note: PDF files require Adobe Acrobat Reader*.
Intel developed the Installation guides for Windows* Server 2016, Red Hat* Enterprise Linux*, and SUSE* Linux* Enterprise Server with step-by-step instructions to work around this issue and to load the updated ASPEED* video driver v1.03. These documents are already included in every System Update Package (firmware) release.
Affected products
Product Code | MM# |
---|---|
S2600WFT | 952641 |
S2600WF0 | 952644 |
S2600WFQ | 952645 |
S2600BPB | 948899 |
S2600BPQ | 948900 |
S2600BPS | 952609 |
S2600STB | 957180 |
S2600STQ | 957318 |
Related topic
Installation guides for Windows* Server 2016, Red Hat* Enterprise Linux*, and SUSE* Linux* Enterprise Server