TA-1012: Field Replaceable Unit (FRU) Can Fail to Update Properly
TA-1012: Field Replaceable Unit (FRU) Can Fail to Update Properly (PDF)
This document describes the root cause and corrective action for a rare occurrence when using the Intel® Server Board S2400SC Family with PBA version G18552-402. The error occurs when an attempt is made to update the FRUSDR, resulting in the message Error: Unknown Error.
Size: 45 KB
Date: June 2012
Revision: 1.0