Tested Chassis List for Intel® Workstation Board S5520SC
This page contains tested chassis list for the Intel® Workstation Board S5520SC. It consists of 2 sections:
Tested Intel® chassis list:
The table below contains the tested Intel® Server Chassis list for the Intel® Workstation Board S5520SC.
Tested Intel® Server Chassis | Description | Notes |
SC5600Base | Intel® Server Chassis, 670W fixed PSU, 3 fixed chassis fans with ducting, 1 PSU fan. Supports up to 6 tool-free cabled drives, upgradeable to 6 hot-swap drives (SAS or SATA). Supports up to 95W processor. No power cord or heat sinks included. | |
SC5650WS | Intel® Server Chassis, 1000W fixed PSU, supports up to two 150W workstation graphics cards or single 300W workstation graphics card, 3 fixed chassis fans with ducting, rackable with optional rack kit, supports up to 6 fixed drives, upgradeable to 6 Hot-Swap drives (SAS or SATA). Supports up to 130W processor. No power cord or heat sinks included. |
Reference chassis list:
The reference chassis listed below includes the third party chassis that were tested to determine whether they provide adequate airflow to keep critical server components within the individual manufacturer's temperature specifications for Intel® Workstation Board S5520SC.
Vendor | Model | Chassis Type | Power Supply | Thermal Test Level | Drive Support | EMC | Note |
Chenbro* | SR105 | Pedestal | Internal power supply | 1 | C | ||
Chenbro* | SR107 | Pedestal | Internal power supply | 1 | C | ||
Chenbro* | RM21706 | 2U | single | 1 | C | ||
Chenbro* | RM31212 | 3U | single | 1 | C | ||
Chenbro* | RM31408 | 3U | single | 1 | C | ||
Yeong Yang* | W203T | 5U | single | 1 | C | ||
CI Design* | NSR212 | 2U | R/D | 1 | C | ||
CI Design* | NSR208 | 2U | R/D | 1 | C |
Notes
Additional chassis may be undergoing testing. Results will be posted as they become available.
- Chassis legend:
- 1U = Rack (U is multiple of 1.75 inches)
- 2U = Rack (U is multiple of 1.75 inches)
- 5U = Rack (U is multiple of 1.75 inches)
- Power supply:
- R/D = Redundant
- H/S = Hot Swap Redundant
- Thermal test level:
- Intel performs system level thermal testing of a given Intel Server Board in all listed 3rd party reference chassis. The server board is configured to use a generic fan control scheme which operates all attached system fans at 100% pulse width modulation (PWM). The generic fan control scheme is set by selecting the OTHER CHASSIS option using the FRUSDR Configuration Utility.
Intel cannot guarantee that specific system configurations will remain within maximum thermal limits if users choose to modify and reduce the fan control PWM rate from the tested configuration. Users that choose to modify the fan control PWM rate are wholly responsible for all required thermal validation to ensure their system configurations stay within specified maximum thermal limits. - Refers to the highest level of testing that successfully completed Intel's thermal testing. The chassis configuration summary is provided below:
Level Board Revisions Processor Maximum Speed Mfg. Processor Tech Number of Drives Maximum Ambient Temperature (C) 1 All Intel® Xeon® Processor X5500 Sequence 2.93 GHz 45nm 2 35 - Intel performs system level thermal testing of a given Intel Server Board in all listed 3rd party reference chassis. The server board is configured to use a generic fan control scheme which operates all attached system fans at 100% pulse width modulation (PWM). The generic fan control scheme is set by selecting the OTHER CHASSIS option using the FRUSDR Configuration Utility.
- Drive support option legend:
Option Designator Supported Drive Type A Docking SAS B Docking SATA C Cabled (SAS or SATA)
The testing information is provided as a guide for the reseller in choosing chassis products that are compatible with the Intel® Workstation Board S5520SC. The reseller is encouraged to test the chassis products in specific configurations.
IMPORTANT INFORMATION AND DISCLAIMERS: The content of the Web site links located in the tested chassis list is not controlled by Intel. These links are being offered for your convenience and should not be viewed as an endorsement by Intel of the content, products, or services offered there. This listing is not intended to be all inclusive, nor is it an endorsement by Intel; it only represents chassis Intel has examined to date. Users of this list are reminded to check with the chassis manufacturer to get latest model specifications and ensure a particular chassis model is adequate for the user's intended purposes. This list is subject to change at any time. Check this web site regularly for updates. For purposes of future server board introductions, Intel may test current and additional chassis, which may result in a revision of this chassis list. Intel reserves the right to modify this document at any time without notice. Intel assumes no responsibility for any errors which may appear in this document, nor does it make any commitment to update the information contained in it. Intel disclaims any liability or obligation for damages of any kind arising out of the application or use of the information contained in this document.
INTEL DISCLAIMS ALL WARRANTIES AND GUARANTEES, EXPRESS, IMPLIED OR OTHERWISE, ARISING FROM OR CONCERNING THE CONTENTS OF THIS DOCUMENT, INCLUDING, BUT NOT LIMITED TO, THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND ANY WARRANTY OF NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT OF ANY THIRD PARTY. INTEL MAKES NO CLAIMS OF COMPLIANCE WITH ANY GOVERNMENTAL REGULATORY AGENCY.
Intel does not convey any license, express, implied or statutory, by estoppel or otherwise, arising under its intellectual property rights, nor under the rights of others. This information is for reference use by PC integrators only. PC integrators are not authorized to refer to Intel's testing or reporting activities in advertising or any other manner.