get_number_of_columns (::quartus::report)
The following table displays information for the get_number_of_columns Tcl command:
Tcl Package and Version |
Belongs to ::quartus::report 1.0 |
|||
Syntax | get_number_of_columns [-h | -help] [-long_help] [-id <table_id> ] [-name <table_name> ] | |||
Arguments | -h | -help | Short help | ||
-long_help | Long help with examples and possible return values | |||
-id <table_id> | Id of panel from which to get data | |||
-name <table_name> | Name of panel from which to get data | |||
Description |
Returns the number of columns for the specified panel. Using the panel id provides faster data access than using the panel name. Panel ids that you have cached may become outdated or invalid if the report is unloaded or reloaded. This error occurs after compilation or with calls to the "project_close", "unload_report", and "load_report" commands. Panel names support wildcards. The table of contents portion of the Compilation Report window shows short panel names for better readability. However, the panel name used by this command is the full panel name as shown in the right-hand side frame of the Compilation Report window or the .rpt file of the corresponding command-line executable. For example, the table of contents shows the path "Analysis & Synthesis||Summary". However, the corresponding full path used by this Tcl command is "Analysis & Synthesis||Analysis & Synthesis Summary". |
|||
Example Usage |
## Loop through a panel row and print out all its element information load_package report project_open chiptrip load_report # Set panel name and id set panel {*Input Pins} set id [get_report_panel_id $panel] if {$id == -1} { error( "Panel not found") } # Get the number of columns set col_cnt [get_number_of_columns -id $id] # Set row name and get row index set rname {*clk1*} set rindex [get_report_panel_row_index -id $id $rname] set rname [get_report_panel_data -row $rindex -col 0 -id $id] puts "\[Input Pins - $rname\]" for {set i 1} {$i < $col_cnt} {incr i} { set result "[get_report_panel_data -row 0 -col $i -id $id]: " append result [get_report_panel_data -row $rindex -col $i -id $id] puts $result } unload_report project_close |
|||
Return Value | Code Name | Code | String Return | |
TCL_OK | 0 | INFO: Operation successful | ||
TCL_OK | 0 | INFO: Report automatically reloaded because it was not up-to-date after use of Tcl command execute_flow or execute_module (which belong to ::quartus::flow package). No action is required. | ||
TCL_ERROR | 1 | ERROR: Can't find the top-level panel. Make sure the loaded report is not empty. You can run a successful compilation to rebuild the report. | ||
TCL_ERROR | 1 | ERROR: Can't find panel: <string>. Specify an existing report panel name. | ||
TCL_ERROR | 1 | ERROR: Report not loaded for revision name: <string>. Type load_report to load the report. | ||
TCL_ERROR | 1 | ERROR: Can't access report panel. Use this command only for report panels with rows or columns. |