trigger position Definition

A feature that allows you to specify the amount of data to acquire before the trigger and the amount to acquire after the trigger in the selected instance captured by the Signal Tap Logic Analyzer.



Acquired data is placed in a circular buffer, with the newest samples replacing the oldest. When triggered, the Signal Tap Logic Analyzer continues sampling the input signals to capture post-trigger data. You can set the ratio of pre-trigger to post-trigger data saved in the sample buffer as follows:

Pre

Save signal activity that occurred after the trigger (12% pre-trigger, 88% post-trigger).

Center

Save half pre-trigger and half post-trigger data.



Post

Save signal activity that occurred before the trigger (88% pre-trigger, 12% post-trigger).

The exact trigger position can be overwritten or specified with the state-based trigger flow command <segment_trigger>.