CLK-30035: Clock Pairs Missing Physically Exclusive Clock Group Assignment
Description
Violations of this rule identify two base clocks defined on the same target and are clocking the same register without a physically-exclusive clock group assignment.
Recommendation
Add set_clock_group -physically_exclusive assignment to clocks reported.
Severity
High
Tags
Tag | Description |
---|---|
sdc | Design rule checks related to SDC validity checking. |
Device Family
- Intel®Cyclone® 10 GX
- Intel®Arria® 10
- Intel®Stratix® 10
- Intel®Agilex™