CLK-30035: Clock Pairs Missing Physically Exclusive Clock Group Assignment

Description

Violations of this rule identify two base clocks defined on the same target and are clocking the same register without a physically-exclusive clock group assignment.

Recommendation

Add set_clock_group -physically_exclusive assignment to clocks reported.

Severity

High

Tags

Tag Description
sdc Design rule checks related to SDC validity checking.

Device Family

  • Intel®Cyclone® 10 GX
  • Intel®Arria® 10
  • Intel®Stratix® 10
  • Intel®Agilex™