TMC-20313: Paths Failing Hold Analysis with Locally Routed Clock

Description

Violation of this rule identifies hold failing paths that use local routing resources in their clock path. As compared to local routing resources global resources have much less min max spread and consquently reduce the amount of clock skew.

Parameters

Name Description Type Default Value Min Value Max Value
maximum_hold_slack Reports a violation for timing paths that have a hold slack below the value of this parameter. double 0.0    
to_clock_filter Reports a violation for timing paths that end at a register in a clock domain that matches the value of this parameter. string *    

Recommendation

If there are no more global resources available and the number of clocks cannot be reduced, the number of fan-outs should be reduced to prevent having to route as far, this will decrease the skew present. Otherwise the associated node on the clock path should be promoted to global routing using the QSF "set_instance_assignment -name GLOBAL_SIGNAL GLOBAL_CLOCK -to <instance_name>".

Severity

Medium

Tags

Tag Description
global-signal  
clock-skew  

Device Family

  • Intel® Stratix® 10
  • Intel® Agilex™
  • Intel® Arria® 10
  • Intel® Cyclone® 10 GX