LNT-30023: Reset Nets with Polarity Conflict
Description
This rule verifies whether a driver drives the SCLR (or CLRN) ports of multiple registers with opposite polarities. This condition can be common if you connect the wrong reset polarity to a block of logic, or code the wrong polarity in you RTL.
When the reset is released and most of the logic is toggling, the registers with the wrong polarity are held in reset. In addition, these registers in simulation and hardware appear to be "stuck at 0 or 1".
Note:
The
Intel
Quartus
Prime Pro Edition synthesis can synthesize regular datapath logic to use the SCLR port of a register. In that case, Design Assistant may indicate a rule violation, even though no actual logic reset is present. Confirm that the driver is actually a system reset, or if either of the signals are coded with the wrong reset polarity. If not, you can waive the rule violation.
Recommendation
Verify the intended polarity of the reset nets, and modify the RTL to unify the reset polarity.
Severity
Medium
Tags
Tag | Description |
---|---|
reset-usage |
Device Family
- Intel® Arria® 10
- Intel® Agilex™
- Intel® Stratix® 10