CLK-30002: Clock Source Driving Non-clock Pins

Description

This rule detects issues that are not reported by more specific clock structures, such as:

  • Multiplexed clocks
  • Clock dividers that are not based on synchronous counters or state-machines
  • D-latches based on the asynchronous load feature

When a design contains clock signal sources that connect to ports other than clock ports, the design is asynchronous and has associated issues and challenges of asynchronous designs.

The following figure shows an example of a clock signal source that incorrectly drives the input pin of an AND gate:

Figure 1. Clock Signal Source That Incorrectly Drives the Input Pin of an AND Gate

Recommendation

The clock signal source in a design should drive only clock input ports of registers. Correct any unintended connectivity.

Severity

High

Device Family

  • Intel® Arria® 10
  • Intel® Cyclone® 10 GX