CLK-30002: Clock Source Driving Non-clock Pins
Description
This rule detects issues that are not reported by more specific clock structures, such as:
- Multiplexed clocks
- Clock dividers that are not based on synchronous counters or state-machines
- D-latches based on the asynchronous load feature
When a design contains clock signal sources that connect to ports other than clock ports, the design is asynchronous and has associated issues and challenges of asynchronous designs.
The following figure shows an example of a clock signal source that incorrectly drives the input pin of an AND gate:
Recommendation
The clock signal source in a design should drive only clock input ports of registers. Correct any unintended connectivity.
Severity
High
Device Family
- Intel® Arria® 10
- Intel® Cyclone® 10 GX