PDI-20101: Platform Designer Interconnect Burst Adapter Timing Violation

Description

Design contains failing path between Platform Designer interconnect components. This condition is due to the use of generic converter burst adapter.

Recommendation

To improve timing of the interconnect, use per-burst-type converter burst adapter. This implementation is faster than the generic burst adapter. Perform the following:

  • In Platform Designer, open the Platform Designer system that has this violation.
    Figure 1. Platform Designer System
  • In the right-hand pane, go to DomainsInterconnect ParametersDomain tab.
  • Change the Burst adapter implementation parameter to use the Per-burst-type converter (faster, higher area) option using the drop-down menu.
Figure 2. Burst Adapter Implementation

Severity

Medium

Device Family

  • Intel® Agilex™
  • Intel® Stratix® 10