View Page (Signal Tap Logic Analyzer) (Options Dialog Box)
Show horizontal grid:
Allows you to display the horizontal grid in the waveform file. The default is on.
Nodes & groups:
Allows you to control the display of lines.
- Low value thickness— Specifies the thickness of the line that represents low value logic conditions.
- High value thickness— Specifies the thickness of the line that represents high value logic conditions.
- Inter-line spacing— Allows you to increase the vertical size of the waveform rows. 0 is the minimum height, and the default.
Align names:
Allows you to select the alignment of the node names in the Node Name column in the Signal Tap window. You can select Left or Right.
Group bits:
Specifies whether group bits are displayed with either the MSB or the LSB first.
Show leading zeros in group values:
Determines whether hexadecimal, binary, or octal numbers displayed in the Signal Tap Logic Analyzer window are shown with or without leading zeros. The default is on.
Show time grid:
Allows you to display the horizontal lines of the time grid in a waveform file, or the vertical lines of the time grid in a Signal Tap waveform file.
Show time bars:
Allows you to display the horizontal lines of the time grid in a waveform file, or the vertical lines of the time grid in a Signal Tap waveform file.
State-based trigger flow:
Allows you to set the default window display mode for the State Machine pane in the State-based Trigger Flow tab.