ID:18868 Clock signal <name> was given conflicting Clock Region and Custom Clock Tree assignments: <cons1> and <cons2>
CAUSE: Conflicting clock region assignments were found for the specified signal.
ACTION: Only specify a single Clock Region assignment for a particular signal. Redundant Clock Region assignments are only permitted if they are all identical.