Auto Open-Drain Pins logic option
Directs the Compiler to automatically convert a tri-state buffer with a strong low data input into the equivalent open-drain buffer, as illustrated in the following code example:
IF (EN = '0') THEN OD_Pin <= 'Z'; ELSE OD_Pin <= '0'; END IF;
This option cannot be used with netlists that are synthesized with third-party synthesis tools. To use this option, you must turn on the Perform WYSIWYG Primitive Resynthesis logic option.
This option must be assigned to a design entity or it is ignored. This option can be used in conjunction with the Weak Pull-Up Resistor option to pull the bus to VCC. This option is available for all Intel devices that the Intel® Quartus® Prime software supports.
Scripting Information |
Keyword: auto_open_drain_pins Settings: on* | off *default |