Parameters

text-align:left;

Parameter

Type

Required

Description

INCLOCK_PERIOD

Integer

No

Specifies the period of the inclock port in picoseconds (ps) time unit Definition This parameter is not required if a Clock Settingstiming assignment is specified for the inclock port. This port is required for simulation with other EDA simulators.

INCLOCK_SETTINGS

String

No

Specifies the Clock Settings assignment to be used with the inclock port. If the INCLOCK_SETTINGS parameter is specified, the INCLOCK_PERIOD parameter is not required and is ignored. If omitted, the default is "UNUSED".

VALID_LOCK_CYCLES

Integer

No

This parameter is available only for obsoleted device families.

INVALID_LOCK_CYCLES

Integer

No

This parameter is available only for obsoleted device families.

VALID_LOCK_MULTIPLIER

Integer

No

This parameter is available only for obsoleted device families.

INVALID_LOCK_MULTIPLIER

Integer

No

This parameter is available only for obsoleted device families.

OPERATION_MODE

String

No

This parameter is available only for obsoleted device families.

CLOCK0_BOOST

Integer

No

Specifies the integer multiplication factor, which must be greater than 0, for the clock0 port with respect to the input clock frequency. This parameter can be specified only if the clock0 port is used; however, it is not required if a Clock Settings assignment is specified for the clock0 port. If omitted, the default is 1.

CLOCK0_DIVIDE

Integer

No

Specifies the integer division factor, which must be greater than 0, for the clock0 port with respect to the input clock frequency. This parameter can be specified only if the clock0 port is used; however, it is not required if a Clock Settings assignment is specified for the clock0 port. If omitted, the default is 1.

CLOCK0_SETTINGS

String

No

Specifies the Clock Settings assignment to be used with the clock0 port. If this parameter is specified, the CLOCK0_BOOST, CLOCK0_DIVIDE, and OUTCLOCK_PHASE_SHIFT parameters are not required and are ignored. If more than one of the CLOCK<value>_SETTINGS parameters are specified, they must have the same phase shift. If omitted, the default is "UNUSED".

CLOCK1_BOOST

Integer

No

Specifies the integer multiplication factor, which must be greater than 0, for the clock1 port with respect to the input clock frequency. This parameter can be specified only if the clock1 port is used; however, it is not required if a Clock Settings assignment is specified for the clock1 port. If omitted, the default is 1.

CLOCK1_DIVIDE

Integer

No

Specifies the integer division factor, which must be greater than 0, for the clock1 port with respect to the input clock frequency. The parameter can be specified only if the clock1 port is used; however, it is not required if a Clock Settings assignment is specified for the clock1 port. If omitted, the default is 1.

CLOCK1_SETTINGS

String

No

Specifies the Clock Settings assignment to be used with the clock1 port. If this parameter is specified, the CLOCK1_BOOST, CLOCK1_DIVIDE, and OUTCLOCK_PHASE_SHIFT parameters are not required and are ignored. If more than one of the CLOCK<value>_SETTINGS parameters are specified, they both must have the same phase shift. If omitted, the default is "UNUSED".

OUTCLOCK_PHASE_SHIFT

Integer

No

This parameter is available only for obsoleted device families.