Unused Inputs to Primitives, Megafunctions and Macrofunctions

The following rules apply to unconnected input ports on primitive, megafunction, and macrofunction symbols and instances.

  • Unused inputs to flipflop primitives have the following defaults:

    CLRN:

     

    VCC (inactive)

    PRN:

     

    VCC (inactive)

    ENA:

     

    VCC (active)

    The data and clock inputs to flipflops and the data and ENA inputs to latches are required.

  • An unused OE input to a TRI buffer defaults to VCC (active, output enabled).
  • Unused inputs to logic primitives in Block Editor files must be connected to VCC or GND.
  • The default logic levels for unused inputs to megafunctions, if any, are documented in the Help for each megafunction. There may not be a default input to some ports on megafunctions, and failure to connect such ports causes the Compiler to issue error messages.