probe_ccu_main_Probe_Filters_1_SecurityBase

         CCU Probe Filter 1 Security Base Register
      
Module Instance Base Address Register Address
i_noc_ccu_ios_probe_ccu_main_Probe 0xFFD22400 0xFFD22494

Size: 32

Offset: 0x94

Access: RW

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

Reserved

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Reserved

FILTERS_1_SECURITYBASE

RW 0x0

probe_ccu_main_Probe_Filters_1_SecurityBase Fields

Bit Name Description Access Reset
1:0 FILTERS_1_SECURITYBASE
Register SecurityBase contains the security base used to filter packets.