WDT_EOI

         Interrupt Clear Register.
      
Module Instance Base Address Register Address
i_watchdog_0_wdt_address_block 0xFFD00200 0xFFD00214
i_watchdog_1_wdt_address_block 0xFFD00300 0xFFD00314
i_watchdog_2_wdt_address_block 0xFFD00400 0xFFD00414
i_watchdog_3_wdt_address_block 0xFFD00500 0xFFD00514

Size: 32

Offset: 0x14

Access: RO

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

Reserved

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Reserved

wdt_eoi

RO 0x0

WDT_EOI Fields

Bit Name Description Access Reset
0 wdt_eoi
Clears the watchdog interrupt. This can be used to clear the interrupt
without restarting the watchdog counter.
RO 0x0