probe_emac_main_Probe_TraceAlarmStatus
EMAC Probe Trace Alarm Status Register
Module Instance | Base Address | Register Address |
---|---|---|
i_noc_ccu_ios_probe_emac_main_Probe | 0xFFD22800 | 0xFFD2281C |
Size: 32
Offset: 0x1C
Access: RO
Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
Reserved |
|||||||||||||||
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
Reserved |
TRACEALARMSTATUS RO 0x0 |
probe_emac_main_Probe_TraceAlarmStatus Fields
Bit | Name | Description | Access | Reset |
---|---|---|---|---|
2:0 | TRACEALARMSTATUS |
Register TraceAlarmStatus is a read-only register that indicates which lookup table or filter has been matched by a packet, independently of register TraceAlarmEn bit configuration. The number of bits in TraceAlarmStatus is determined by the value set for parameter nFilter + 1.When nFilter is set to None, TraceAlarmStatus is reserved. |
RO | 0x0 |