siliconid2

         Reserved for future use.
This is a read only register and a write should return error.
      
Module Instance Base Address Register Address
i_sys_mgr_core 0xFFD12000 0xFFD12004

Size: 32

Offset: 0x4

Access: RO

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

rsv

RO 0x0

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

rsv

RO 0x0

device_revision

RO 0x0

siliconid2 Fields

Bit Name Description Access Reset
31:4 rsv
Reserved for future use.
RO 0x0
3:0 device_revision
SDM writes the device revision value from fuses to HPS secure manager.
Secure manager drives this value to system manager.
RO 0x0