read_mode

         The type of read sequence that the controller will follow for pipe read commands. 
      
Module Instance Base Address Register Address
i_nand_config 0xFFB80000 0xFFB801C0

Size: 32

Offset: 0x1C0

Access: RW

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

Reserved

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Reserved

value

RW 0x0

read_mode Fields

Bit Name Description Access Reset
3:0 value
 The values in the field should be as follows[list]
                             [*]4'h0 - This value informs the controller that the pipe read sequence to follow is of
                                    a normal read. 
                                    For 512 byte page devices, Normal read sequence is,
                                    C00, Address, Data, .....
                                    For devices with page size greater that 512 bytes, the sequence is,
                                    C00, Address, C30, Data.....
                             [*]4'h1 - This value informs the controller that the pipe read sequence to follow is of
                                    a Cache Read with the following sequence,
                                    C00, Address, C30, C31, Data, C31, Data, ....., C3F, Data.
                             [*]4'h2 - This value informs the controller that the pipe read sequence to follow is of
                                    a Cache Read with the following sequence,
                                    C00, Address, C31, Data, Data, ....., C34.
                             [*]4'h3 - This value informs the controller that the pipe read sequence to follow is of
                                    a 'N' Plane Read with the following sequence,
                                    C00, Address, C00, Address, C30, Data, C06, Address, CE0, Data.....
                             [*]4'h4 - This value informs the controller that the pipe read sequence to follow is of
                                    a 'N' Plane Read with the following sequence,
                                    C60, Address, C60, Address, C30, C00, Address, C05, Address, CE0, Data, C00,
                                    Address, C05, Address, CE0, Data.....
                             [*]4'h5 - This value informs the controller that the pipe read sequence to follow is of
                                    a 'N' Plane Cache Read with the following sequence,
                                    C60, Address, C60, Address, C30, C31, C00, Address, C05, Address, CE0, Data, 
                                    C00, Address, C05, Address, CE0, Data, ....., C3F, C00, Address, C05, Address, 
                                    CE0, Data, C00, Address, C05, Address, CE0, Data
                             [*]4'h6 - This value informs the controller that the pipe read sequence to follow is of
                                    a 'N' Plane Read with the following sequence,
                                    C00, Address, C32, .., C00, Address, C30, C06, Address, CE0, Data, 
                                    C06, Address, CE0, Data,....
                             [*]4'h7 - This value informs the controller that the pipe read sequence to follow is of
                                    a 'N' Plane Cache Read with the following sequence,
                                    C00, Address, C32,..., C00, Address, C30, C31,C06, Address, CE0, Data, 
                                    C31, C06, Address, CE0, Data, C3F, C06, Address, CE0, Data....
                             [*]4'h8 - This value informs the controller that the pipe read sequence to follow is of
                                    a 'N' Plane Cache Read with the following sequence,
                                    C60, Address, C60, Address, C33, C31, C00, Address, C05, Address, CE0, Data, 
                                    C00, Address, C05, Address, CE0, Data, ....., C3F, C00, Address, C05, Address, 
                                    CE0, Data, C00, Address, C05, Address, CE0, Data
                             [*]4'h9 - 4'h15 - Reserved.
                             [/list]
                             ..... indicates that the previous sequence is repeated till the last page. 
RW 0x0