probe_emac_main_Probe_FilterLut
EMAC Probe Filter Lookup Table Register
Module Instance | Base Address | Register Address |
---|---|---|
i_noc_ccu_ios_probe_emac_main_Probe | 0xFFD22800 | 0xFFD22814 |
Size: 32
Offset: 0x14
Access: RW
Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
Reserved |
|||||||||||||||
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
Reserved |
FILTERLUT RW 0x0 |
probe_emac_main_Probe_FilterLut Fields
Bit | Name | Description | Access | Reset |
---|---|---|---|---|
3:0 | FILTERLUT |
Register FilterLut contains a look-up table that is used to combine filter outputs in order to trace packets. Packet tracing is enabled when the FilterLut bit of index (FNout ... F0out) is equal to 1.The number of bits in register FilterLut is determined by the setting for parameter nFilter, calculated as 2**nFilter.When parameter nFilter is set to None, FilterLut is reserved. |
RW | 0x0 |