vcocalib

         VCO calibration control registers.
      
Module Instance Base Address Register Address
i_clk_mgr_perpllgrp 0xFFD100A4 0xFFD100FC

Size: 32

Offset: 0x58

Access: RW

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

Reserved

termin

RW 0x0

Reserved

mscnt

RW 0x5

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

mscnt

RW 0x5

Reserved

hscnt

RW 0xBF

vcocalib Fields

Bit Name Description Access Reset
24:23 termin
Termination Calibration Control Look-Up Table Select
RW 0x0
16:9 mscnt
mscnt = 200/(fvco/fref). 
It can be only set while the PLL is at reset or power down state. 
It cannot be switched dynamically. 
RW 0x5
7:0 hscnt
VCO calibration parameter. 
hscnt= (mdiv+ 6) * mscnt/ refdiv-9.
It can be only set while the pll is at reset or power down state. 
It cannot be switched dynamically.

RW 0xBF