SMMU_CB6_TLBIVA_high

         Invalidates all of the unlocked TLB entries that match both the VA provided and the TLB tagging scheme of the context bank, including any global entries if appropriate
      
Note: For register and programming information, please refer to the Arm® CoreLink™ MMU System Memory Management Unit Technical Reference Manual.
Module Instance Base Address Register Address
i_aps_smmu_secure_registers 0xFA000000 0xFA026604

Size: 32

Offset: 0x26604

Access: WO

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

ASID

WO 0x0

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Reserved

Address

WO 0x0