SMMU_CB8_TLBSYNC
Initiates a synchronization operation that ensures the completion of any TLB invalidate operations previously accepted in the corresponding translation context bank.
Note: For register and programming information, please refer to the Arm® CoreLink™ MMU System Memory Management Unit Technical Reference Manual.
Module Instance | Base Address | Register Address |
---|---|---|
i_aps_smmu_secure_registers | 0xFA000000 | 0xFA0287F0 |
Size: 32
Offset: 0x287F0
Access: WO
Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
bits WO 0x0 |
|||||||||||||||
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
bits WO 0x0 |